Technical Information

Architectural specifications, warranties, overhang requirements, finishing guides, and fire/STC ratings.

Warranties & Exterior Overhang Protection

Coverage terms, warp tolerances, exclusions, and required roof overhang formulas for Hardwood and Environmental (MDF) doors.

1. Limited Warranty Coverage Comparison

Term / Parameter Hardwood Doors (Solid Wood) Environmental Doors (Recycled MDF)
Residential Term
  • 2 Years — Custom Solid Hardwood Doors
  • Limited Lifetime — Factory-primed Environmental MDF Doors
Unprimed / Commercial Residential applications from date of shipment (Phoenix, AZ). 1 Year Limited for unprimed or commercial doors (unprimed doors must be primed on all 6 surfaces immediately after acclimating).
Warp Tolerance (Max 1/4") Not considered a defect if warp ≤ 1/4" in plane of door:
  • 1 3/8" thick: up to 3'0" × 7'0"
  • 1 3/4" thick: up to 3'6" × 8'0"
  • 2 1/4" thick: up to 4'0" × 8'0"
Not considered a defect if warp ≤ 1/4" in plane of door for any door up to 4'0" × 8'0" × 1 3/4".
Oversized Door Rules
  • Larger than 3'6" × 8'0": min 2 1/4" thick
  • Wider than 3'6": min 2 vertical rows of panels
  • 4'0" and wider: min 3 vertical rows of panels
Standard maximum size 4'0" × 8'0" (fire-rated doors require compliance with ITS machining specs).
Exclusive Remedy At EDC's option: (1) repair the door, (2) ship a replacement door in the same condition of fitting/finishing as originally sold, or (3) refund the original purchase price. EDC never pays for labor, installation, removal, or finishing costs.

Items Not Considered Defects (Exclusions)

  • Unsealed Surfaces: Failure to equally seal/finish all 6 surfaces (front, back, top, bottom, and both side edges) immediately after fitting and hanging.
  • Missing Overhang Protection: Exterior installation without adequate overhang protection from direct sunlight and precipitation.
  • Frame & Hardware Issues: Bow or misalignment in the frame/jamb, or improper hardware mortising/sizing.
  • Storm Door Heat Buildup: Extreme thermal buildup behind an unvented storm door (storm doors must be vented).
  • Finish & Wood Variations: Natural variations in wood color, density, or grain texture; or unsatisfactory gloss/texture from non-EDC finishes.
  • Misuse & Geography: Misuse, accidents, acts of nature, failure to follow care instructions, doors used as gates, or doors shipped outside the US or Canada.

Inspection & Warranty Claims Procedure

  • Pre-Installation Inspection: Report all visible defects or shipping mistakes to EDC before trimming or hanging; otherwise the door is deemed accepted.
  • Original Purchaser Only: Coverage applies only to the original purchaser of the door or initial structure and is non-transferable.
  • Written Claim Submission: Submit claims in writing within the warranty period and before starting any repairs to:
    Executive Door Company, 3939 W. Clarendon Ave., Phoenix, AZ 85019
  • Required Claim Info: Include purchase date and location, detailed problem description, and claimant name, address, and phone number.
  • Field Inspection: EDC must be granted a reasonable opportunity for an authorized representative to inspect the door on site.

2. Exterior Overhang Protection Requirements

  • Warranty Requirement: All exterior Hardwood and Environmental doors must be protected by an adequate roof overhang to shield against direct Desert Southwest sun and moisture.
  • Projection Calculation: Measure height Y (from bottom of door to bottom of overhang) to determine minimum overhang projection X (outward from the door face):
    • North Exposure: Overhang projection X = 1/2 × Y
    • South, East & West Exposures: Overhang projection X = Y to 2Y depending on climate severity
  • Color & Heat Management: Where overhang depth is limited, finish exterior doors in a light color to minimize thermal absorption.
Exterior Door Roof Overhang Calculation Diagram
Required Overhang Projection Relative to Door Height & Exposure